TH56 iTHERM CableLine Cable Probe

$300.00

 

TH56 iTHERM CableLine Cable probe is used in many process and laboratory applications such as heat exchangers, furnaces or dryers. Without additional thermowell the probe sheath is directly in contact with the process medium. This enables the cable probe to detect rapid temperature changes fast and accurate.

 

SKU: iTHERM-TH56 Categories: , Tags: ,

Description

Field of application

TH56 is sensor with plug connection is easy to install and provide a high operational safety due to reliable and accurate temperature measurement in common processes. The probe is used in many process and laboratory applications such as heat exchangers, furnaces or dryers. Without additional thermowell the probe sheath is directly in contact with the process medium. This enables the cable probe to detect rapid temperature changes fast and accurate.

Magnesium oxide insulated thermocouples, commonly referred to as MgO thermocouples, are used in many process and laboratory applications. They have many desirable characteristics making thermocouples a good choice for general and special purpose applications.

The sensors can be used on:

  • Heat exchangers

  • Power & recovery areas

  • Furnaces

  • Dryers

  • Flue gas

  • Compressor stations

  • Process reactors

Benefits

  • Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor and transmitter assembly for a complete point solution.

  • Improved galvanic isolation on most devices (2 kV)

  • One source shopping for temperature measurement solutions. Remove and install straight out of the box!

  • All iTEMP® transmitters provide long term stability ≤ 0.05 % per yea.

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Thermocouple

Characteristic / Application

Industrial US style
cable probe
process connection as compression fitting

Thermowell / protection tube

without (not intended to use with thermowell)

Insert / probe

mineral insulated (MI), flexible

Outer diameter protection tube / Insert

1/16'' (1,59 mm)
1/8'' (3,18 mm)
3/16'' (4,76 mm)
1/4'' (6,35 mm)

Max. immersion length on request

up to 96" (2438 mm)
others on request

Material protection tube/ thermowell

Sensor sheath
316
Alloy 600

Process connection

compression fitting:
NPT1/8"
NPT1/4"

Tip shape

straight

Operating temperature range

Type T:
-270 °C …370 °C
(-454 °F …698 °F)
Type J:
-210 °C …720 °C
(-346 °F …1.328 °F)
Type E:
-270 °C …820 °C
(-454 °F …1.508 °F)
Type K:
-270 °C …1.150 °C
(-454 °F …2.102 °F)
Type N:
-270 °C … 1.150 °C
(-454 °F …2.102 °F)

Max. process pressure (static)

Standard acc. to ASTM E-230
Special acc. to ASTM E-230

Accuracy

Standard acc. to ASTM E-230
Special acc. to ASTM E-230

Response time

63% rt = 0,3 s

Integration head transmitter

no

Ex - approvals

ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6
ATEX II1D Ex ia IIIC, II1G Ex ia IIC T6
ATEX II1G Ex ia IIC T6
ATEX II 3 G Ex nA IIC T6, II3D
NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450
EAC Ex ia
UK II1G Ex ia IIC T6 Ga
UK II1/2D Ex ia IIIC Da/Db, II1G Ex ia IIC T6 Ga
UK II1D Ex ia IIIC Da, II1G Ex ia IIC T6 Ga
UK II 3 G Ex nA IIC T6 Gc, II3D Ex tc IIIC Dc
IECEx Ex ia IIC T6 Ga
NEPSI Ex nA IIC T6

Reviews

There are no reviews yet.

Be the first to review “TH56 iTHERM CableLine Cable Probe”