TAF12D iTHERM FlameLine High Temperature Thermometer

$2,120.00

Endress+Hauser

iTHERM TAF12D was made from ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

  • The TAF12D are assemblies with double ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.

  • Process temperatures: up to +1700 °C (+3092 °F)

 

Description

Field of application

Measuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell and the internal sheath made from ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

  • The TAF12D are assemblies with double ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.

  • Process temperatures: up to +1700 °C (+3092 °F)

Benefits

  • Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance

  • Long term stable measurement due to sensor protection with non-porous materials

  • Flexible product selection by modular design

  • Optimized life cycle costs by means of replaceable spare parts

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Thermocouple

Characteristic / Application

metric style
modular temperature assembly
high temperature probe (furnace)
incl. double ceramic thermowell

Thermowell / protection tube

ceramic protection tube and inner tube

Insert / probe

ceramic capilarry, rigid

Outer diameter protection tube / Insert

14,0 mm (0,55")
15,0 mm (0,59")

Max. immersion length on request

up to 3.500,00 mm (137,80'')

Material protection tube/ thermowell

Ceramic (C610/C799)

Process connection

compression fitting:
G3/4"
G1"
G11/2"
adjustable Flange

Tip shape

straight

Operating temperature range

Type S:
0 °C …1.600 °C
(32 °F …2.912 °F)
Type R:
0 °C …1.600 °C
(32 °F …2.912 °F)
Type B:
600 °C …1.700 °C
(1.112 °F …3.092 °F)

Max. process pressure (static)

at 20 °C: 1 bar (15 psi)

Accuracy

class 2 acc. to IEC 60584

Integration head transmitter

yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Certification

SIL (transmitter only)

Reviews