PMD55 Differential Pressure Deltabar

$760.00

Endress+Hauser

PMD55 Differential Pressure Deltabar allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 / IEC 61511.

For level, volume or mass measurement in liquids, differential pressure monitoring, e.g. of filters and pumps as well as flow measurement (volume or mass flow) in conjunction with primary elements in gases, vapors and liquids.
  • Process connections: Threads

  • Process temperature: -40 to 85°C (-40 to 185°F)

  • Measuring ranges: 0.5mbar to 40bar (0.0072 to 600psi)

  • Accuracy: ±0.1%, “Platinum” ±0.075% (optional)

  • International explosion protection certificates, SIL

 

Description

Deltabar PMD55 – differential pressure transmitter

Differential pressure transmitter with metal sensor for measurement of pressure differences

Field of application

The electronic dp Deltabar FMD72 is a differential pressure system, used to measure the pressure, level, volume or mass of liquids in pressurized tanks or distillation columns/evaporators. The high pressure sensor (HP) measures the hydrostatic pressure. The low pressure sensor (LP) measures the head pressure. The level is calculated in the transmitter using these two digital values. The electronic dp system eliminates issues of traditional differential pressure measurements.

For differential pressure, level, volume or mass measurement of liquids in pressurized tanks and distillation columns/evaporators.
  • Process connections: Threads, flanges and hygienic connections

  • Process temperature: -40 to +125°C (-40 to +257°F), optional 250°C (480°F)

  • Measuring range: 400mbar to +40bar (6 to 600psi)

  • Accuracy: Single sensor up to ±0.05%, system up to ±0.07%

  • International explosion protection certificates, hygienic approvals

Benefits

  • Eliminates traditional mechanical issues resulting in greater process availability and reliability

  • Safety risks are minimized with the new electronic differential pressure system architecture and design

  • Lowest total cost of ownership due to reduced installation time, maintenance, downtime and spare requirements

  • Multivariable level measurement: HART-based differential pressure, head pressure and sensor temperatures from one system

  • Continuous health indication of the entire system via HART-based diagnostic

  • High reproducibility and long-term stability

  • Process safety assured with small flush mounted process connections in hygienic applications

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Differential pressure

Product headline

Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability

Max. measurement error

0,1%
"PLATINUM" 0,075%

Max. process pressure

10mbar…40bar
(0.15…580psi)

Medium temperature range

Temperature gradient from pressure piping

Display/Operation

Option

Outputs

4…20mA HART

Digital communication

HART

Hazardous area approvals

ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS

Functional safety

SIL

Material certificates

NACE MR0103
NACE MR0175
EN10204-3.1

Reviews

There are no reviews yet.

Be the first to review “PMD55 Differential Pressure Deltabar”