FTW32 Conductive Point Level Detection Liquipoint

$799.00

Endress+Hauser

The Liquipoint FTW32 0ffers numerous measuring possibilities due to multipoint detection (up to 5 rods).

For use in conductive liquids (as of 10μS/cm). For overfill prevention, dry running protection, two-point control of pumps or multiple point detection.
  • Process connections: Threads

  • Sensor length: 0.25 to 15m (10 to 590″)

  • Temperature: -40 to 70°C (-40 to 158°F)

  • Pressure: -1 to 10bar (-14.5 to 145psi)

  • International explosion protection certificates, overfill prevention and leakage detection certificate WHG

 

Description

Field of application

The Liquipoint FTW32 offers simple and safe point level detection in conductive liquids. It offers numerous measuring possibilities due to multipoint detection (up to 5 rods).

For use in conductive liquids (as of 10μS/cm). For overfill prevention, dry running protection,

two-point control of pumps or multiple point detection.

  • Process connections: Threads

  • Sensor length: 0.25 to 15m (10 to 590″)

  • Temperature: -40 to 70°C (-40 to 158°F)

  • Pressure: -1 to 10bar (-14.5 to 145psi)

  • International explosion protection certificates, overfill prevention and leakage detection certificate WHG

Benefits

  • Cost-effective probe for conductive liquids with detection of up to five point levels with one probe

  • No calibration required

  • Standard setting for the most common conductive liquids

  • No moving parts in the tank – long service life, reliable operation with no wear or blockages

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Conductive

Characteristic / Application

Compact rope probe with multi point detection possible up to 5 switch points. Simple rope shortening possible

Supply / Communication

DC PNP 10,8V … 45V
Relay 20V … 230V AC
Relay 20V … 55V DC

Ambient temperature

-40 °C … 70 °C
(-40 °F … 158 °F)

Process temperature

-40 °C … 70 °C
(-40 °F … 158 °F)

Process pressure / max. overpressure limit

Vacuum … 10 bar
(Vacuum … 145 psi)

Min. conductivity of medium

10 µS/cm

Main wetted parts

316L, FEP, PPS

Max. tensile strength

500 N

Process connection

G 1 1/2
NPT1 1/2"

Sensor length

0.25m … 15m
(10" … 590")

Communication

DC PNP
Relay

Certificates / Approvals

ATEX, EAC Ex

Safety approvals

Leakage Detection

Components

Transmitter: FTW325

Application limits

Observe min. medium conductivity

Reviews

There are no reviews yet.

Be the first to review “FTW32 Conductive Point Level Detection Liquipoint”