FTI51 Capacitance Point Level Detection Liquicap

$799.00

Endress+Hauser

Liquicap FTI51 is a rod probe for point level detection of liquids that are highly viscous and tend to form build-up.

Due to its active build-up compensation FTI51 offers maximum reliability and is suited for a wide range of applications thanks to international certificates.

  • Process connections: Flanges, threads, special hygienic process connections

  • Temperature: -80 to +200°C (-112 to +392°F)

  • Pressure: Vacuum to +100bar (vacuum to +1,450psi)

  • Sensor length: 6m (20ft)

 

Description

Field of application

Liquicap FTI51 is a rod probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids. Due to its active build-up compensation FTI51 offers maximum reliability and is suited for a wide range of applications thanks to international certificates. The parts in contact with the process are made of corrosion-resistant and FDA-listed materials – this guarantees a high safety standard.

For liquids that tend to form build-up. Interface detection of different liquids. Two-point control (pump control) with just one process connection. Foam detection of conductive liquids.
  • Process connections: Flanges, threads, special hygienic process connections

  • Temperature: -80 to +200°C (-112 to +392°F)

  • Pressure: Vacuum to +100bar (vacuum to +1,450psi)

  • Sensor length: 6m (20ft)

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval

Benefits

  • Cost savings thanks to easy and fast commissioning as calibration takes place at the press of a button

  • Reliable and safe measurement due to active build-up compensation

  • Reliable and universal application thanks to wide range of certificates and approvals

  • Short reaction time

  • Material in contact with the process made of corrosion-resistant and FDA-listed materials

  • Two-stage overvoltage protection

  • No need for recalibration after replacing electronics

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Capacitive Liquid

Characteristic / Application

Capacitive rod probe

Specialities

Interface detection
Foam detection

Ambient temperature

-50 °C … +70 °C
(-58 °F … +158 °F)
With separate housing:
-50 °C … +120 °C
(-58 °F … +248°F)

Process temperature

-80 °C … +200 °C
(-112 °F … +392 °F)

Process pressure / max. overpressure limit

Vacuum … 100 bar
(Vacuum … 1450 psi)

Main wetted parts

Insulation material: PTFE, PFA
316L

Process connection

G 1/2 … 1 1/2
NPT 1/2 … 1 1/2
Flange from DN25…/ASME 1"…/JIS 10K…

Process connection hygienic

Tri-Clamp ISO2852 gap free plated
Dairy coupling
Flush mount

Sensor length

Total length of probe: max 6 m (20 ft)

Communication

2- wire 19-253 VAC
3-wire
PFM
Relay DPDT
DC-PNP
8/16 mA

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC

Safety approvals

Overfill prevention WHG
SIL

Design approvals

EN 10204-3.1
NACE MR0175

Marine approval

GL/ ABS/ DNV

Options

Inactive length
Fully isolated active build-up compensation
Ground tube
Separate housing

Components

Transmitter
PFM: FTC325, FTC625, FTC470Z, FTC471Z
3-wire:
FTC325

Application limits

Notice the pressure and temperature derating.
Notice for non conductive medium the DK.

Reviews

There are no reviews yet.

Be the first to review “FTI51 Capacitance Point Level Detection Liquicap”