FTC260 Capacitance Point Level Detection Minicap

$780.00

Endress+Hauser

Minicap FTC260 is designed for point level detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

Typical applications: Grain products, flour, milk powder, animal feed, cement, chalk or gypsum.
  • Process connection: Threads

  • Temperature: -40 to +80°C (-40 to +176°F)

  • Pressure: -1 to +25bar (-14.5 to +360psi)

  • Sensor length: 140mm (5.51″)

  • International explosion protection certificates, overfill prevention WHG

 

Description

Field of application

Minicap FTC260 is a simple and cost-effective rod probe for point level detection in bulk solids, particularly suited to applications involving aggressive media and heavy build-up. It is designed for point level detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

For point level detection of light bulk solids, with a grain size up to max. 30mm and a dielectric constant εr ≥ 1.6.

Typical applications: Grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

  • Process connection: Threads

  • Temperature: -40 to +80°C (-40 to +176°F)

  • Pressure: -1 to +25bar (-14.5 to +360psi)

  • Sensor length: 140mm (5.51″)

  • International explosion protection certificates, overfill prevention WHG

Benefits

  • Simple mounting and commissioning without calibration

  • Mechanical safety, cost-efficiency and long operating life due to no wearing parts

  • High operational safety and reliability due to active build-up compensation

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Capacitive Solid

Characteristic / Application

Compact rod probe with build-up compensation
easy start up

Specialities

FDA-listed material

Supply / Communication

10,8 … 45V DC, DC-PNP 3-wire
20 … 253V AC, or
20 … 55V DC, Relay output

Ambient temperature

-40°C…+70°C
(-40°F…+158°F)

Process temperature

-40°C …+120°C
(-40°F …+248°F)

Process pressure / max. overpressure limit

-1 … 25 bar
(-14.5 … 360 psi)

Main wetted parts

PPS = Polyphenylene sulphide
(glass fibre content approx. 40%)

Process connection

R1"
NPT1"

Sensor length

140 mm (5.51")

Communication

PNP transistor output
Relay output (potential-free
change-over contact / SPDT)

Certificates / Approvals

ATEX , IEC Ex, FM, CSA, NEPSI, UK Ex

Option

Aluminium Housing

Application limits

Solids, grain size max. 30 mm (1.2"),
DK min 1,6
Flexural strength 1400 N (at probe tip)