FMU40 Ultrasonic Measurement Time-of-Flight Prosonic

$400.00

Endress+Hauser

The Prosonic FMU40 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs.

The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.

  • Process connection: Thread

  • Temperature: -40 to +80°C (-40 to +176°F)

  • Pressure: +0.7 to +3bar (+10 to +44psi)

 

Description

Field of application

The Prosonic FMU40 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.

Two-wire or four-wire instrument for continuous non-contact level and flow measurement.
  • Process connection: Thread

  • Temperature: -40 to +80°C (-40 to +176°F)

  • Pressure: +0.7 to +3bar (+10 to +44psi)

  • Maximum measuring distance: Liquids 5m (16ft), Solids 2m (16ft)

  • Blocking distance: Liquids and Solids 0.25m (0.8ft)

  • International explosion protection certificates

Benefits

  • Reliable non-contact measurement

  • Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable

  • Envelope curves on the on-site display for simple diagnosis

  • Hermetically sealed and potted sensor

  • Chemically resistant sensor out of PVDF

  • Calibration without filling or discharging

  • Integrated temperature sensor for automatic correction of the temperature dependent sound velocity

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Ultrasonic

Characteristic / Application

Compact ultrasonic transmitter

Supply / Communication

2-wire HART

Accuracy

+/- 2 mm or +/- 0.2 % of set measuring range

Ambient temperature

-40 °C … 80 °C
(-40 °F … 176 °F)

Process temperature

-40 °C … 80 °C
(-40 °F … 176 °F)

Process pressure / max. overpressure limit

0.7 bar … 3 bar abs
(10 psi … 44 psi)

Main wetted parts

PVDF

Process connection

G / NPT 1 1/2"

Blocking distance

0.25 m (0.8 ft)

Max. measurement distance

Liquids: 5 m (16 ft),
Solids: 2 m (6.6 ft)

Communication

4…20 mA HART

Certificates / Approvals

ATEX, FM, CSA, TIIS, INMETRO, NEPSI

Application limits

For higher resistance:
FMU42/FDU9x
Foam / high turbulence possible:
FMU41/FDU91
Fast filling and discharging rate:
FMU90 + FDU9x
Level limit detection:
FMU90 + FDU9x