FMP55 Guided Radar Measurement Time-of-Flight Levelflex

$1,950.00

Endress+Hauser

Levelflex FMP55 guarantees safe measured value acquisition even in emulsion layers and issues level and interface layer signals simultaneously.

Version with rod, rope or coax probe.

  • Process connections: Thread or flange

  • Temperature: -50 to +200°C (-58 to +392°F)

  • Pressure: -1 to +40bar (-14.5 to +580psi)

  • Accuracy: Rod ±2mm (0.08″)

  • International explosion protection certificates, overfill prevention WHG, SIL, marine approval

 

Description

Field of application

Levelflex FMP55 guided radar with SensorFusion offers the worldwide first combination of the capacitance and guided radar measuring principle in one device. The instrument guarantees safe measured value acquisition even in emulsion layers and issues level and interface layer signals simultaneously. This makes the FMP55 Multiparameter the new standard in interface measurement especially in the oil & gas, chemical and petrochemical industry.

Version with rod, rope or coax probe.
  • Process connections: Thread or flange

  • Temperature: -50 to +200°C (-58 to +392°F)

  • Pressure: -1 to +40bar (-14.5 to +580psi)

  • Maximum measuring range: Rod 4m (13t), rope 10m (33ft), coax 6m (20ft)

  • Accuracy: Rod ±2mm (0.08″)

  • International explosion protection certificates, overfill prevention WHG, SIL, marine approval

Benefits

  • Reliable measurement even for changing product and process conditions

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Highest reliability due to new Multi-Echo Tracking evaluation

  • Hardware and software developed according to IEC 61508 up to SIL3

  • Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle

  • Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)

  • Worlds easiest proof test for SIL and WHG saves time and costs

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Guided radar

Characteristic / Application

Premium device Multiparameter (capacitance and guided radar)
Rod probe, Rope probe, Coaxial probe
Integrated data memory, Factory precalibrated, Reliable measuring: for interface with emulsion, in case of moved surface + foam, for changing medias.

Interface measurement

Interfaces liquid / liquid also with emulsion layers;
Simultaneous measurement of interface and overall level

Specialities

Heartbeat Technology,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
HistoROM,
RFID TAG for easy identification

Supply / Communication

2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Bluetooth® wireless technology and App (optional)

Accuracy

Rod probe :
+/- 2 mm (0.08 in)
Rope probe:
+/- 2 mm (0.08 in)
Coaxial probe:
+/- 2 mm (0.08 in)

Ambient temperature

-40…+80 °C
(-40…+176 °F)

Process temperature

-40…+200 °C
(-40…+392 °F)

Process pressure / max. overpressure limit

Vacuum…40 bar
(Vacuum…580 psi)

Main wetted parts

Rod probe:
316L, PTFE, PFA
Rope probe:
316, 316L, PTFE, PFA
Coaxial probe:
316L, PTFE, PFA

Process connection

Flange:
ASME 1 1/2"…6",
DN50…DN150,
JIS 10K

Sensor length

Rod probe: 4 m (13 ft)
Rope probe: 10 m (33 ft)
Coaxial probe: 6 m (20 ft)

Max. measurement distance

Rod: 4 m (13 ft)
Min DK >1.4
Rope: 10 m (33 ft)
Min DK >1.4
Coaxial: 6 m (20 ft)
Min DK >1.4

Communication

4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology

Certificates / Approvals

ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex

Safety approvals

SIL

Design approvals

EN 10204-3.1
NACE MR0175, MR0103
ASME B31.1, B31.3
AD2000

Marine approval

GL/ ABS/ LR/ BV/ DNV/ KR

Options

Sensor remote with 3 m/ 9 ft cable,
Remote operation via SmartBlue App using Bluetooth®

Reviews

There are no reviews yet.

Be the first to review “FMP55 Guided Radar Measurement Time-of-Flight Levelflex”