FMP52 Guided Radar Measurement Time-of-Flight Levelflex

$1,750.00

Endress+Hauser

Levelflex FMP52 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement.

Version with rod or rope probe.
  • Process connections: Flange or process connections for hygiene requirements (Tri-Clamp, 11851)

  • Temperature: -50 to +200°C (-58 to +392°F)

  • Pressure: -1 to +40bar (-14.5 to +580psi)

  • Maximum measuring range: Rod 4m (13ft), rope 45m (148ft)

  • Accuracy: Rod probe ±2mm (0.08″)

 

Description

Field of application

Levelflex FMP52 for level measurement in aggressive liquids with chemically resistant gap-free PFA-coated probe. All wetted parts are FDA listed materials. FMP52 guided radar offers maximum reliability even in case of moved surface. Levelflex FMP52 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Version with rod or rope probe.
  • Process connections: Flange or process connections for hygiene requirements (Tri-Clamp, 11851)

  • Temperature: -50 to +200°C (-58 to +392°F)

  • Pressure: -1 to +40bar (-14.5 to +580psi)

  • Maximum measuring range: Rod 4m (13ft), rope 45m (148ft)

  • Accuracy: Rod probe ±2mm (0.08″)

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval, 5-point linearity protocol

Benefits

  • Reliable measurement even for changing product and process conditions

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Highest reliability due to new Multi-Echo Tracking evaluation

  • Hardware and software developed according to IEC 61508 up to SIL3

  • Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle

  • Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)

  • World’s easiest proof test for SIL and WHG saves time and costs

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Guided radar

Characteristic / Application

Premium device coated for corrosive media
Rod probe, Rope probe
Wetted parts FDA listed materials, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias.

Interface measurement

Clean interfaces liquid/ liquid;
Simultaneous measurement of interface and overall level

Specialities

Heartbeat Technology,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
HistoROM,
RFID TAG for easy identification

Supply / Communication

2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Bluetooth® wireless technology and App (optional)

Accuracy

Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)

Ambient temperature

-40…+80 °C
(-40…+176 °F)

Process temperature

-50…+200 °C
(-58…+392 °F)

Process pressure / max. overpressure limit

Vacuum…40 bar
(Vacuum…580 psi)

Main wetted parts

Rod probe:
304, 304L, 316L, PTFE, PFA
Rope probe:
304, 304L, 316, 316L, PTFE, PFA

Process connection

Flange:
ASME 1 1/2"…6",
DN50…DN100,
JIS 10K

Process connection hygienic

Tri-Clamp
DIN11851

Sensor length

Rod probe: 4 m (13 ft)
Rope probe: 45 m (148 ft)

Max. measurement distance

Rod:
4 m (13 ft) Min DK>1.6
Rope:
25 m…30 m (82 ft…98 ft) Min DK>1.6;
30 m…45 m (98 ft…148 ft) Min DK>1,9

Communication

4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology

Certificates / Approvals

ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex

Safety approvals

Overfill protection WHG
SIL

Design approvals

EN 10204-3.1
ASME B31.1, B31.3
AD2000

Hygienic approvals

3A, EHEDG

Marine approval

GL/ ABS/ LR/ BV/ DNV

Options

Sensor remote with 3 m/ 9 ft cable,
Gas-tight feed through,
Remote operation via SmartBlue App using Bluetooth®

Application limits

Application limits

Reviews

There are no reviews yet.

Be the first to review “FMP52 Guided Radar Measurement Time-of-Flight Levelflex”