FMI51 Capacitance Level Measurement Liquicap

$788.00

Endress+Hauser

Liquicap FMI51 is a reliable fully insulated rod probe for continuous level monitoring in liquids, particularly in build-up forming media and extremely high temperatures.

Liquicap is an ideal solution for Inventory Management Solutions.

  • Process connections: Flanges and threads
  • Process pressure: Vacuum to +100bar (vacuum to +1,450psi)

  • Measuring range: 0.1 to 4.0m (0.3 to 13ft)

  • Temperature: -80 to +200°C (-112 to +392°F)

 

Description

Field of application

Liquicap FMI51 is a reliable fully insulated rod probe for continuous level monitoring in liquids, particularly in build-up forming media and extremely high temperatures. The measurement is independent of the dielectric constant (dc). Used in conjunction with Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.

The device is independent of the dielectric constant (dc) as of a liquid conductivity of 100μS/cm and allows measurement of various liquids without the need for recalibration.
  • Process connections: Flanges and threads

  • Process pressure: Vacuum to +100bar (vacuum to +1,450psi)

  • Measuring range: 0.1 to 4.0m (0.3 to 13ft)

  • Temperature: -80 to +200°C (-112 to +392°F)

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals

Benefits

  • Use also in safety systems requiring functional safety to SIL2 in accordance with IEC 61508

  • Reliable and universal application thanks to wide range of certificates and approvals

  • No calibration necessary (factory preconfiguration). No calibration necessary for media with a conductivity of 100μS/cm and higher

  • Material in contact with the process made of corrosion-resistant material, FDA-listed materials

  • Menu-guided local configuration via plain text display (optional)

  • Two-stage overvoltage protection

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Capacitive Liquid

Characteristic / Application

Fully insulated rod probe, for standart- and extreme process conditions (temperature, pressure, build-up)

Interface measurement

Interfaces liquid / liquid also with emulsion layers

Specialities

Inactive length
Factory calibrated
short response time by change of value

Supply / Communication

12-36V DC HART
PFM

Accuracy

Repeatablity 0,1%

Linearity error for conductive liquids

<0,25%

Ambient temperature

-50°C…+70°C
-58°F…+158°F

Process temperature

-80°C…200°C
-112°F…392°F

Process pressure / max. overpressure limit

Vacuum … 100 bar
(Vaccum … 1450 psi)

Main wetted parts

Insulation material: PTFE,PFA
316L

Process connection

G1/2, G 3/4, G 1, G1 1/2 /NPT 1/2, NPT 3/4, NPT 1", NPT1 1/2
Flanges from DN25…/ASME 1"…/JIS…

Process connection hygienic

Tri-Clamp ISO02852 gap free plated
Dairy coupling
Flush-mounted seal

Sensor length

Total length: 6m (20ft)
Inactive length: max. 2m (7ft)

Max. measurement distance

0.1 m … 4.0 m
(0.3 ft … 13 ft)

Communication

4…20mA HART
PFM

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC

Safety approvals

SIL

Design approvals

EN 10204-3.1
NACE MR0175

Hygienic approvals

3A, EHEDG

Marine approval

GL/ ABS/ DNV

Options

Separate housing
gas-tight probe seal

Application limits

Insufficient clearance towards ceiling
Changing, non-conductive
media, conductivity
< 100 μS/cm
Notice the pressure and temperature derating