FMD78 Differential Pressure Deltabar

$790.00

Endress+Hauser

The Deltabar FMD78 differential pressure transmitter with metal sensor uses two capillary diaphragm seals.

Typically used in process and hygiene applications for continuous measurement of pressure differences in liquids, vapors, gases and dusts.

The integrated HistoROM data module makes the management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety applications.

For differential pressure, level, volume or mass measurement in liquids.
  • Process connections: Threads, flanges, pancake and hygienic connections

  • Process temperature: -70 up to +400°C (-94 to +752°F)

  • Measuring ranges: 100mbar to +40 bar (1.5 to 600psi)

  • Accuracy: ±0.075%

 

Description

Deltabar FMD78 – differential pressure transmitter

Differential pressure transmitter with two diaphragm seals for differential pressure and level

Field of application

The Deltabar FMD78 differential pressure transmitter with metal sensor uses two capillary diaphragm seals. Typically used in process and hygiene applications for continuous measurement of pressure differences in liquids, vapors, gases and dusts. The integrated HistoROM data module makes the management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety applications.

For differential pressure, level, volume or mass measurement in liquids.
  • Process connections: Threads, flanges, pancake and hygienic connections

  • Process temperature: -70 up to +400°C (-94 to +752°F)

  • Measuring ranges: 100mbar to +40 bar (1.5 to 600psi)

  • Accuracy: ±0.075%

  • International explosion protection certificates, overfill prevention WHG, hygienic approvals, marine approvals, SIL

Benefits

  • Large variety of different process connections and membrane materials

  • New TempC Membrane for diaphragm seals: Minimum temperature effects and short recovery times

  • Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508

  • Easy menu-guided commissioning via local display, 4 to 20 mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Cost savings with modular concept for easy replacement of sensor, display or electronics

  • Seamless and independent system integration (HART/PA/FF)

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Differential pressure

Characteristic

Digital transmitter with metallic measuring diaphragms diaphragm seals and capillaries
Modular transmitter
Long-term stability
Secondary process barrier
enhanced safety via self diagnostic functions.

Supply voltage

4…20 mA HART
10,5…45V DC (Non Ex):
Ex ia: 10,5…30V DC
PROFIBUS PA:
9…32 V DC (Non Ex)
FOUNDATION Fieldbus:
9…32 V DC (Non Ex)

Reference Accuracy

0,075% + influence of diaphragm seal

Long term stability

0.08 % of URL/ year
0.14 % of URL/ 5 years
0.27 % of URL/ 10 years

Process temperature

-70°C…400°C
(-94°F…752°F)

Ambient temperature

-50°C…85°C
(-58°F…185°F)

Measuring cell

100 mbar…40 bar
(40 inH2O…600 psi)

Smallest calibratable span

5 mbar (0.075 psi)

Vacuum resistance

50 mbar (0.73 psi)

Max. Turn down

100 : 1

Max. overpressure limit

160 bar
(2400 psi)

Process connection

Diaphragm seal (Pancake, threads)
Flanges (DIN, ASME)
Hygienic connections
Tri-Clamp ISO2852

Process connection hygienic

Tri-Clamp
DIN11851
NEUMO
Varivent
SMS
DRD
Universal adapter

Material process membrane

316L, AlloyC,
Tantal,
Gold-Rhodium
PTFE

Material gaske

None, diaphragm seal welded

Fill fluid

Silicone oil,
Inert oil,
Vegetable oil
Low- temperature oil
High- temperature oil

Material housing

316L, Die-cast aluminum

Communication

4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex

Safety approvals

SIL

Design approvals

NACE MR0175
EN10204-3.1

Hygienic approvals

3A, FDA

Marine approvals

GL/ ABS

Specialities

Diagnostic functions
TempC Membrane

Successor

PMD78B

Reviews

There are no reviews yet.

Be the first to review “FMD78 Differential Pressure Deltabar”