FMB52 Hydrostatic Level Measurement Deltapilot

$1,300.00

Endress+Hauser

Deltapilot FMB52 is a cable version including a fixed process connection.

This device with the Contite measuring cell is typically used in the process and environmental industries.

  • Process connections: Threads and flanges
  • Temperature: With PE cable: -10 to +70°C (+14 to +158°F),

    with FEP cable: -10 to +80°C (14 to 176°F)

  • Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)

  • Accuracy: ±0.2%, ±0.1% (option)

 

Description

Field of application

The Deltapilot FMB52 is a cable version including a fixed process connection. This device with the Contite measuring cell is typically used in the process and environmental industries. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. For use in SIL2 safety systems.

For level measurement.
  • Process connections: Threads and flanges

  • Temperature: With PE cable: -10 to +70°C (+14 to +158°F),

    with FEP cable: -10 to +80°C (14 to 176°F)

  • Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)

  • Accuracy: ±0.2%, ±0.1% (option)

  • International explosion protection certificates, overfill prevention WHG, SIL, drinking water approval

Benefits

  • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects

  • Modular concept for easy replacement of display or electronics

  • Seamless and independent system integration (HART/PA/FF)

  • Easy and safe menu-guided operation: On-site via display module, via 4 to 20mA with HART, via PROFIBUS PA, via FOUNDATION Fieldbus

  • International usage thanks to a wide range of approvals

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Hydrostatic pressure

Characteristic / Application

Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Cable version

Supply voltage

4…20 mA HART
10,5…45 VDC (Non Ex):
Ex ia: 10,5…30 VDC
PROFIBUS PA:
9…32 VDC (Non Ex)
FOUNDATION Fieldbus:
9…32 VDC (Non Ex)

Reference Accuracy

Standard 0.2%
Optional 0.1%

Long term stability

0.05 % of URL/year

Process temperature

PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F

Ambient temperature

-40°C…85°C
(-40°F…185°F)

Measuring cell

100 mbar…10 bar
(1.5 psi…150 psi)

Smallest calibratable span

10 mbar (1.45 psi)

Vacuum resistance

0 mbar abs.

Max. Turn down

100:1

Max. overpressure limit

40 bar (600 psi)

Process connection

Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40…DN100,
ASME 2"…4",
JIS 10K

Material process membrane

316L, AlloyC,
Gold-Rhodium
PE, FEP

Material gasket

Viton, EPDM, Kalrez, none

Fill fluid

Inert oil,
Synthetic oil

Material housing

316L, Die-cast aluminum

Communication

4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex

Safety approvals

Overfill protection WHG
SIL

Design approvals

EN10204-3.1
NACE MR0175

Marine approvals

GL/ ABS/ LR/ BV/ DNV

Drinking water approvals

KTW/ NSF/ ACS

Specialities

Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
Diagnostic functions

Reviews

There are no reviews yet.

Be the first to review “FMB52 Hydrostatic Level Measurement Deltapilot”

Your email address will not be published. Required fields are marked *