FMB51 Hydrostatic Level Measurement Deltapilot

$1,250.00

Endress+Hauser

The Deltapilot FMB51 is a rod version with a fixed process connection.

It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation.

For use in SIL2 safety systems.

For level measurement.
  • Process connections: Threads and flanges

  • Temperature: -10 to +85°C (14°F…185° F)

  • Accuracy: ±0.2%, ±0.1% (option)

 

Description

Field of application

The Deltapilot FMB51 is a rod version with a fixed process connection. This device with the Contite measuring cell and is typically used in the environmental industry. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. For use in SIL2 safety systems.

For level measurement.
  • Process connections: Threads and flanges

  • Temperature: -10 to +85°C (14°F…185° F)

  • Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)

  • Accuracy: ±0.2%, ±0.1% (option)

  • International explosion protection certificates, overfill prevention WHG, SIL, drinking water approval

Benefits

  • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects

  • Modular concept for easy replacement of display or electronics

  • Seamless and independent system integration (HART/PA/FF)

  • Easy and safe menu-guided operation: On-site via display module, via 4 to 20mA with HART, via PROFIBUS PA, via FOUNDATION Fieldbus

  • International usage thanks to a wide range of approvals

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Hydrostatic pressure

Characteristic / Application

Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Rod version

Supply voltage

4…20 mA HART
10,5…45 VDC (Non Ex):
Ex ia: 10,5…30 VDC
PROFIBUS PA:
9…32 VDC (Non Ex)
FOUNDATION Fieldbus:
9…32 VDC (Non Ex)

Reference Accuracy

Standard 0.2 %
Optional 0.1 %

Long term stability

0.05 % of URL/year

Process temperature

-10°C…85°C
(14°F…212°F)

Ambient temperature

-40°C…85°C
(-40°F…185°F)

Measuring cell

100 mbar…10 bar
(1.5 psi…150 psi)

Smallest calibratable span

10 mbar (1.45 psi)

Vacuum resistance

0 mbar abs.

Max. Turn down

100:1

Max. overpressure limit

40 bar (600 psi)

Process connection

Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40…DN100,
ASME 2"…4",
JIS 10K

Material process membrane

316L, AlloyC
Gold-Rhodium

Material gasket

Viton, EPDM, Kalrez, none

Fill fluid

Inert oil,
Synthetic oil

Material housing

316L, Die-cast aluminum

Communication

4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex

Safety approvals

Overfill protection WHG
SIL

Design approvals

EN10204-3.1
NACE MR0175

Drinking water approvals

KTW/ NSF

Specialities

Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
Diagnostic functions

Reviews