FMB50 Hydrostatic Level Measurement Deltapilot

$1,200.00

Endress+Hauser

Deltapilot FMB50 is typically used in the process and hygienic applications.

It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation.

  • Process connections: Thread, flanges and flush-mounted hygienic connections

  • Process temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)

  • Measuring range: 0.1 to 10bar (1.5 to 150psi)

  • Accuracy: ±0.2%, ±0.1% (option)

 

Description

Field of application

The compact Deltapilot FMB50 transmitter with the condensate resistant Contite measuring cell is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.

For level and/or pressure measurement.
  • Process connections: Thread, flanges and flush-mounted hygienic connections

  • Process temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)

  • Measuring range: 0.1 to 10bar (1.5 to 150psi)

  • Accuracy: ±0.2%, ±0.1% (option)

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates

Benefits

  • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects

  • Modular concept for easy replacement of display or electronics

  • Seamless and independent system integration (HART/PA/FF)

  • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

  • International usage thanks to a wide range of approvals

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Hydrostatic pressure

Characteristic / Application

Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences

Supply voltage

4…20 mA HART
10,5…45 VDC (Non Ex):
Ex ia: 10,5…30 VDC
PROFIBUS PA:
9…32 VDC (Non Ex)
FOUNDATION Fieldbus:
9…32 VDC (Non Ex)

Reference Accuracy

Standard 0.2 %
Optional 0.1 %

Long term stability

0.05 % of URL/ year

Process temperature

-10°C…100°C
(14°F…212°F)

Ambient temperature

-40°C…85°C
(-40°F…185°F)

Measuring cell

100 mbar…10 bar
(1.5 psi…150 psi)

Smallest calibratable span

10 mbar (1.45 psi)

Vacuum resistance

0 mbar abs.

Max. Turn down

100:1

Max. overpressure limit

40 bar (600 psi)

Process connection

Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40…DN100,
ASME 1 1/2"…4",
JIS 10K

Process connection hygienic

Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD

Material process membrane

316L, AlloyC
Gold-Rhodium

Material gasket

None, measuring cell welded

Fill fluid

Inert oil,
Synthetic oil

Material housing

316L, Die-cast aluminum

Communication

4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
IO-Link

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex

Safety approvals

Overfill protection WHG
SIL

Design approvals

EN10204-3.1
NACE MR0103

Hygienic approvals

3A, EHEDG
CoC ASME-BPE

Marine approvals

GL/ ABS/ LR/ BV/ DNV

Drinking water approvals

KTW/ NSF/ ACS

Specialities

Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
Diagnostic functions