D5AB Dosimag Electromagnetic Flowmeter

$4,000.00

Endress+Hauser

Dosimag Electromagnetic Flowmeter D5AB measures volume directly. The compact and robust sensor is available with three electronics versions:

  • Pulse/frequency/status version for easy and economical use in filling applications

  • Intelligent pulse version with IO-Link provides continuous digital communication, allowing easy commissioning and documentation, real-time availability of process data, optimization of filling conditions and predictive maintenance

  • Integrated batching version with Dynamic Drip Correction over Modbus RTU for advanced filling control

 

Description

Field of application

Dosimag is designed for demanding filling and bottling applications with conductive liquids in Food & Beverage and Life Sciences. In applications where space is limited, Dosimag is the preferred choice for system integrators, skid builders and equipment manufacturers. Dosimag measures volume directly. The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.

The compact and robust sensor is available with three electronics versions:
  • Pulse/frequency/status version for easy and economical use in filling applications

  • Intelligent pulse version with IO-Link provides continuous digital communication, allowing easy commissioning and documentation, real-time availability of process data, optimization of filling conditions and predictive maintenance

  • Integrated batching version with Dynamic Drip Correction over Modbus RTU for advanced filling control

Benefits

  • High and stable filling performance – high measuring accuracy and repeatability in shortest filling times

  • IO-Link allows real-time digital communication for easier commissioning and continuous data availability

  • Compact design for optimized machine footprint

  • Integrated batching functionality – filling process management solved by the flowmeter

  • Automatic recovery of data for servicing

  • Global compliance with industry standards – EHEDG, 3-A, FCM, cGMP

  • SIP and CIP cleanable

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Electromagnetic

Product Headline

Flowmeter with hygienic design, highest repeatability and an ultra-compact sensor.
For demanding dosing and filling applications.

Sensor features

High process safety – high measuring accuracy and repeatability in shortest filling time. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Wetted materials CIP, SIP cleanable. Nominal diameter: DN 4 to 25 (¹⁄₈ to 1"). Measuring device conform to FDA.

Transmitter features

Versatile and time-saving wiring – plug connector. Industry-optimized – ultra-compact design. For hygienic requirements – stainless steel housing.
Pulse/frequency/switch output, Modbus RS485. Custody transfer approvals (MID, NTEP). Excellent, easily cleanable transmitter.

Nominal diameter range

DN 4 to 25 (¹⁄₈ to 1")

Wetted materials

Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum,
Platinum

Measured variables

Volume flow, Temperature (DN15-26)

Max. measurement error

±0.25 % o.r. ± 1 to 4 m/s (3.3 to 13 ft/s)

Measuring range

0.14 to 1.66 l/s (0.035 to 0.44 gal/s)

Max. process pressure

PN 16

Medium temperature range

Seal material EPDM: –20 to +130 °C (–4 to +266 °F)
Seal material Silicone: –20 to +130 °C (–4 to +266 °F)
Seal material Viton: 0 to +150 °C (+32 to +302 °F)

Ambient temperature range

–40 to +60 °C (–40 to +140 °F)

Sensor housing material

1.4308 (304)

Transmitter housing material

1.4308 (304)

Degree of protection

IP66/67, type 4X enclosure

Display/Operation

No local Operation
Configuration via operating tools possible

Outputs

Pulse/frequency/switch output (passive)

Digital communication

Modbus RS485, IO-Link

Power supply

DC 20 to 30 V

Hazardous area approvals

ATEX, IECEx, UL, UK Ex

Product safety

CE

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc.to ISO/IEC 17025)
NTEP

Material certificates

3.1 material

Hygienic approvals and certificates

Sanitary approval: 3-A, EHEDG, seals acc. to FDA

Reviews

There are no reviews yet.

Be the first to review “D5AB Dosimag Electromagnetic Flowmeter”

Your email address will not be published. Required fields are marked *