CPS72 Analog ORP Sensor Ceragel

$335.00

Endress+Hauser

CPS72 The sensor is sterilizable, autoclavable and non-toxic assuring highest safety of your products.

  • Hygienic and sterile applications:
    – Fermenters
    – Biotechnology
    – Life sciences
    – Food industry

  • Process technology and monitoring of processes with:
    – Quickly changing pH values
    – High proportion of electrode poisons such as H2S

With ATEX, FM, and CSA approval for application in hazardous areas

 

Description

Field of application

Ceragel CPS72 is the analog specialist for ORP measurement in sterile and hygienic applications. Its state-of-the-art gel is poison resistant and guarantees stable measurement even in flowing media or low conductivity. The sensor is sterilizable, autoclavable and non-toxic assuring highest safety of your products.

  • Hygienic and sterile applications: – Fermenters – Biotechnology – Life sciences – Food industry

  • Process technology and monitoring of processes with: – Quickly changing pH values – High proportion of electrode poisons such as H2S

With ATEX, FM, and CSA approval for application in hazardous areas

Benefits

  • Suitable for CIP/SIP cleaning and autoclaving maintaining high accuracy

  • Sensor resists strong acids and bases and high organic loads

  • Certified biocompatibility, no cytotoxicity

  • Free from animal-based materials and from acrylamide

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Sensor ORP / Redox

Application

– Hygienic and sterile applications – pharmaceuticals, biotechnology, fermenters, contaminating media.

Characteristic

– Gel-compact-electrode with ceramic diaphragm – Platinum-cap – CIP/SIP and autoclavable – high accuracy

Measuring range

–1 500 to 1 500 mV

Material

Glass electrode with ceramic diaphragm and platinum ring.

Dimension

Diameter: 12 mm
Shaft lengths: 120, 225, 360 mm

Process temperature

-15°C – 135°C

Process pressure

max. 16bar

Ex certification

Simple operational device, no certification necessary.

Connection

TOP68 connection head

Ingress protection

IP68

Additional certifications

Biocompatibility acc. ISO 10993-5 and USP (current version).
TÜV certificate for pressure resistance up to 16 bar with triple overpressure safety.

Reviews

There are no reviews yet.

Be the first to review “CPS72 Analog ORP Sensor Ceragel”

Your email address will not be published. Required fields are marked *