9E1B E100 Proline Prosonic Flow Ultrasonic Flowmeter

$3,300.00

Endress+Hauser

Proline Prosonic Flow E100(9E1B) Ultrasonic Flowmeter proves to be a multivariable flowmeter for considerable additional value in your plant. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

  • The measuring principle is independent of pressure, density, temperature and conductivity

  • Bidirectional measuring of demineralized water applications for utilities, e.g. boiler condensate return lines

 

SKU: Proline Prosonic E100(9E1B) Categories: , Tags: ,

Description

Proline Prosonic Flow E100 Ultrasonic Flowmeter

Economical Ultrasonic flowmeter with integrated temperature measurement

Field of application

Measuring of demineralized water in utilities, for example in boiler condensate return lines, requires reliable devices. Prosonic Flow E 100 provides economical and accurate bidirectional flow measurement across all industries. With its integrated temperature measurement, Prosonic Flow E 100 proves to be a multivariable flowmeter for considerable additional value in your plant. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

  • The measuring principle is independent of pressure, density, temperature and conductivity

  • Bidirectional measuring of demineralized water applications for utilities, e.g. boiler condensate return lines

Device properties:

  • Accuracy up to ±0.5 % (flow) or acc. to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temp.)

  • Process temperatures up to 150 °C (302 °F)

  • Entire meter housing made of stainless steel

  • 4-20 mA HART, pulse/frequency output

  • Local display for reading and monitoring available

  • Robust transmitter housing

Benefits

  • Long-term stability – reliable, robust sensor

  • Reducing further measuring point – multivariable device

  • Dependable flow measurement – high turndown (200:1)

  • Time-saving local operation without additional software and hardware – integrated web server

  • Extended calibration intervals – integrated device verification due to Heartbeat Technology

  • Easy commissioning – brief parameter explanations

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Ultrasonic flow

Product Headline

Economical Ultrasonic flowmeter with integrated temperature measurement.
Bidirectional measuring of demineralized water applications for Utilities, e.g. boiler condensate return lines.

Sensor features

Long-term stability – reliable, robust sensor. Reducing further measuring point – multivariable device. Dependable flow measurement – high turndown (200:1).
Measurement accuracy up to ±0.5 % (flow) or according to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temperature). Process temperatures up to 150 °C (302 °F). Entire meter housing made of stainless steel.

Transmitter features

Time-saving local operation without additional software and hardware – integrated web server. Extended calibration intervals – integrated device verification due to Heartbeat Technology. Easy commissioning – brief parameter explanations.
4-20 mA HART, pulse/frequency output. Local display for reading and monitoring available. Robust transmitter housing.

Nominal diameter range

DN 50 to 150 (2"to 6")

Wetted materials

Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105

Measured variables

Volume flow, calculated mass flow, flow velocity, sound velocity, temperature

Max. measurement error

Volume flow:
– ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
– ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)

Measuring range

0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min)

Max. process pressure

PN 25 / ASME Cl. 150

Medium temperature range

0 to 150° (17.8 to 302 °F)

Ambient temperature range

-20 to 60 °C (-4 to 140 °F)

Transmitter housing material

Compact:
AlSi10Mg, coated
Stainless steel, 1.4301

Degree of protection

Standard: IP66/67, Type 4X enclosure
With opened housing: IP20, Type 1 enclosure

Display/Operation

4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible

Outputs

4‐20 mA HART (active)
Pulse/frequency/switch output (passive)

Inputs

None

Power supply

DC 19.2 to 28.8 V

Hazardous area approvals

None

Product safety

CE, C-Tick, EAC marking

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Calibration according to EN 1434 Class 2

Pressure approvals and certificates

PED

Material certificates

3.1 material

Reviews

There are no reviews yet.

Be the first to review “9E1B E100 Proline Prosonic Flow Ultrasonic Flowmeter”

Your email address will not be published. Required fields are marked *