92F Proline Prosonic Flow Ultrasonic Flowmeter

$3,200.00

Endress+Hauser

Proline Prosonic Flow 92F Ultrasonic Flowmeter is ideally suited for the chemical and petrochemical industries.

  • The measuring principle is independent of pressure, density, temperature, conductivity and viscosity

  • Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry

 

SKU: Proline Prosonic 92F Categories: , Tags: ,

Description

Proline Prosonic Flow 92F Ultrasonic Flowmeter

Highly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs

Field of application

Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.

  • The measuring principle is independent of pressure, density, temperature, conductivity and viscosity

  • Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry

Device properties:

  • Full compliance according to NACE MR0175 and MR0103

  • Nominal diameter: DN 25 to 300 (1 to 12″)

  • Medium temperature: –40 to 200 °C (–40 to 392 °F)

  • Device as compact or remote version

  • 2-line backlit display with push buttons

  • HART, PROFIBUS PA, FOUNDATION Fieldbus

Device properties:

  • Medium temperature: –20 to +80 °C (-4 to +176 °F)

  • Degree of protection IP68 (Type 6P enclosure) for pipes under water

  • Shock and vibration resistance according to IEC 68-2-6

  • Aluminium field transmitter housing

  • 2-line display with push buttons

  • HART

Benefits

  • Safe design for process industries – international hazardous area approvals

  • No additional pressure loss – full-bore design

  • Process transparency – diagnostic capability

  • Easy installation and reduced installation costs – loop-powered transmitter

  • Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI

  • Automatic recovery of data for servicing

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Ultrasonic flow

Product Headline

Higly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs.
Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry.

Sensor features

Safe design for process industries – international hazardous area approvals. No additional pressure loss – full-bore design. Process transparency – diagnostic capability.
Full compliance according to NACE MR0175 and MR010. Nominal diameter: DN 25 to 300 (1 to 12"). Medium temperature: –40 to 200 °C (–40 to 392 °F).

Transmitter features

Easy installation and reduced installation costs – loop-powered transmitter. Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI. Automatic recovery of data for servicing.
Device as compact or remote version. 2-line backlit display with push buttons. HART.

Nominal diameter range

2 path version: DN80 to 300 (3 to12")
3 path version: DN25 to 50 (1 to 2")
4 path version: DN 80 to 300 (3 to 12")

Wetted materials

Sensor:
A351-CF3M (DN25 to 100)
1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
Transducer: 1.4404/316/316L
Flanges : 1.4404/316/316L or A105/1.0432

Measured variables

Volume flow, calculated mass flow, sound velocity, flow velocity, signal strength

Max. measurement error

Volume flow (standard):
– ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Volume flow (option):
– ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)

Measuring range

0.5 to 10 m/s (1.6 to 33 ft/s)

Max. process pressure

PN 40 / ASME Cl. 300 / JIS 20K

Medium temperature range

-40 to +150 °C (-40 to +302 °F)
-40 to +200 °C (-40 to +392 °F) optional

Ambient temperature range

-40 to +60 °C (-40 to +140 °F) compact
-40 to +80 °C (-40 to +176 °F) remote sensor
-40 to +60 °C (-40 to +140 °F) remote transmitter

Transmitter housing material

AlSi10Mg, coated

Degree of protection

IP67, type 4X enclosure
IP68 type 6P enclosure (option for remote)

Display/Operation

2 lines backlit display with 3 push buttons

Outputs

1x 4-20 mA HART
1x Pulse/frequency/switch output (passive)

Inputs

N/A

Digital communication

HART

Power supply

2 wire loop powered

Hazardous area approvals

ATEX,FM, CSA, JPNm UK Ex

Other approvals and certificates

3.1 material (wetted parts), calibration performed on accredited
calibration facilities (acc. to ISO/IEC 17025), CRN, AD2000
PED, EAC marking

Product safety

EAC marking

Metrological approvals and certificates

calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Pressure approvals and certificates

CRN, PED, AD2000

Material certificates

3.1 material (wetted parts)