Brand |
Endress+Hauser/E+H
|
Measuring principle |
Coriolis
|
Product Headline |
Compact sensor for smallest quantities with seamless system integration.
Measuring accurately smallest quantities of liquids and gases.
|
Sensor features |
Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor.
Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).
|
Transmitter features |
High flexibility in system integration – wide range of communication interfaces. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing.
Device as compact or remote version. Flexible outputs. Modbus RS485.
|
Nominal diameter range |
DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")
|
Wetted materials |
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
|
Measured variables |
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
|
Max. measurement error |
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm3
|
Measuring range |
0 to 1000 kg/h (0 to 37 lb/min)
|
Max. process pressure |
PN 40, Class 300, 10K, 400 bar (5800 psi)
|
Medium temperature range |
–50 to +200 °C (–58 to +392 °F)
|
Ambient temperature range |
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
|
Sensor housing material |
1.4301 (304), corrosion resistant
|
Transmitter housing material |
Powder‐coated die‐cast aluminium
|
Degree of protection |
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
|
Display/Operation |
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
|
Outputs |
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive), phase‐shifted pulse
Relay
|
Inputs |
1 modular input: status
|
Digital communication |
HART, Modbus RS485
|
Power supply |
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
|
Hazardous area approvals |
ATEX, IECEx, NEC/CEC, NEPSI
|
Other approvals and certificates |
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
CRN
|
Functional safety |
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
|
Metrological approvals and certificates |
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
|
Material certificates |
3.1 material
|
Reviews