Brand |
Endress+Hauser
|
Measuring principle |
Vortex
|
Product headline |
Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy.
Easy energy management – integrated temperature and pressure measurement for steam and gases.
Suitable for a wide range of applications; optimized for steam applications.
|
Sensor features |
Space-saving engineering – inlet run compensation. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor.
Wet steam capabilities for DN 25 to 300 (1 to 12"). Flexible positioning of pressure cell. Industrial siphon design for pressure measurement.
|
Transmitter features |
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
|
Nominal diameter range |
DN 15 to 300 (½ to 12")
|
Wetted materials |
Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602
DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602
Process connection: 1.4404/F316/F316L); 2.4602
|
Measured variables |
Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
|
Max. measurement error |
Volume flow (liquid): ±0.75 %
Volume flow (optional): ±0.65 %
Volume flow (steam, gas): ±1.00 %
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): ±0.85%
|
Measuring range |
Liquid: 0.076 to 2100 m³/h (0.045 to 1300 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
|
Max. process pressure |
PN 100, Class 600, 20K
|
Medium temperature range |
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
|
Ambient temperature range |
Compact version (standard): –40 to +80 °C (–40 to +176 °F)
Compact version (option): –50 to +80 °C (–58 to +176 °F)
Remote version (standard): –40 to +85 °C (–40 to +185 °F)
Remote version (option): –50 to +85 °C (–58 to +185 °F)
|
Sensor housing material |
Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
|
Transmitter housing material |
AlSi10Mg, coated; 1.4404 (316L)
|
Degree of protection |
Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure
|
Display/Operation |
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
|
Outputs |
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
|
Inputs |
Current Input 4‐20 mA (passive)
|
Digital communication |
HART, PROFIBUS PA, FOUNDATION Fieldbus
|
Power supply |
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
|
Hazardous area approvals |
ATEX, IECEx, cCSAus, JPN, EAC
|
Product safety |
CE, C-TICK, EAC, UK Ex
|
Functional safety |
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
|
Metrological approvals and certificates |
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
|
Marine approvals and certificates |
ABS, LR, BV, DNV
|
Pressure approvals and certificates |
PED, CRN, AD 2000
|
Material certificates |
3.1 material
NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)
|