Description
Proline t-mass I500(6I5B)
Insertion flowmeter with long-term stability as remote version with up to 4 I/Os
Field of application
The patented sensor design of t-mass I provides unprecedented measurement stability in thermal insertion mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. The innovative remote transmitter of t-mass I 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and compliant verification.
-
Measuring principle is characterized by a high operable flow range and direct mass flow measurement
-
Measurement of utility and process gases and gas mixtures in circular piping or rectangular ducts
Device properties
-
Insertion version for DN 80 to 1500 (3 to 60″)
-
Bidirectional measurement; high measuring performance
-
Patented drift-free sensor with SIL 2
-
Remote version with up to 4 I/Os
-
Backlit display with touch control and WLAN access
-
Standard cable between sensor and transmitter
Benefits
-
Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
-
High level of process control – premium measurement accuracy and repeatability
-
Reliable monitoring – detection of process disturbances and reverse flow
-
Flexible installation – suitable for large dimensional range and circular pipes or rectangular ducts
-
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
-
Reduced complexity and variety – freely configurable I/O functionality
-
Integrated verification – Heartbeat Technology
Reviews
There are no reviews yet.