6BAB B150 Proline T-mass Thermal Mass Flowmeter

$2,900.00

Endress+Hauser

Proline t-mass B150(6BAB) thermal mass flowmeter

The flowmeter for cost-effective measurement and easy monitoring of utility gases

  • Insertion version for nominal diameter DN 80 to 1500 (3 to 60″)

  • Installation and removal of sensor without process interruption

  • Easy installation

  • Device in compact version with DC 24 V power supply

 

SKU: Proline t-mass B150(6BAB) Categories: , Tags: ,

Description

Proline t-mass B150(6BAB)

thermal mass flowmeter-the flowmeter for cost-effective measurement and easy monitoring of utility gases

Field of application

The t-mass B 150 insertion version is suitable for large pipelines or rectangular ventilation ducts. It is designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at sub-metering applications. Its 4-wire technology is contained within a rugged compact aluminum housing. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.

  • Measuring principle is characterized by a high operable flow range and direct mass flow measurement

  • Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.

Device properties

  • Insertion version for nominal diameter DN 80 to 1500 (3 to 60″)

  • Installation and removal of sensor without process interruption

  • Easy installation

  • Device in compact version with DC 24 V power supply

  • 4-20 mA HART, pulse/frequency/switch output

  • Compact and robust transmitter

Benefits

  • Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts

  • Optimal process monitoring – easy measurement even at low pressures and flow velocities

  • Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free

  • Reliable flow trending – multivariable measurement

  • Fast and efficient commissioning – guided operating menus

  • High plant availability – self-diagnostics and error monitoring

  • Automatic recovery of data for servicing

Additional information

Brand

Endress+Hauser/E+H

Measuring principle

Thermal

Product Headline

The flowmeter for cost-effective measurement and easy monitoring of utility gases.
Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.

Sensor features

Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement.
Insertion version for nominal diameter DN 80 to 1500 (3 to 60"). Installation and removal of sensor without process interruption. Easy installation.

Transmitter features

Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing.
Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter.

Nominal diameter range

DN 80 to 1500 (3 to 60")

Wetted materials

Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L); 1.4435 (316L)
Connection:
Compression fitting: 1.4404 (316L)
Sealing ring: EPDM; HNBR; 1.4401 (316)
Clamping ring: PEEK 450G

Measured variables

Mass flow, temperature, corrected volume flow, FAD volume flow

Max. measurement error

3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")

Measuring range

20 to 720 000 kg/h (45 to 1 587 600 lb/h)
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")

Max. process pressure

20 bar g (290 psi g)

Medium temperature range

–40 to +100 °C (–40 to +212 °F)

Ambient temperature range

–40 to +60 °C (–40 to +140 °F)

Transmitter housing material

AlSi10Mg, coated

Degree of protection

IP66/67, type 4X enclosure

Display/Operation

4‐line display with push Buttons
Configuration via local display and operating tools possible

Outputs

4‐20 mA HART (active)
Pulse/frequency/switch output (passive)

Inputs

Status input

Digital communication

HART

Power supply

DC 18 to 30 V

Hazardous area approvals

ATEX, IECEx, cCSAus

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

Pressure approvals and certificates

CRN