Brand |
Endress+Hauser/E+H
|
Measuring principle |
Electromagnetic
|
Product Headline |
Specialist for hygienic applications, as remote version with up to 4 I/Os.
Dedicated to demanding applications in the food and beverage as well as in life sciences industries.
|
Sensor features |
Flexible installation concept – numerous hygienic process connections. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG). Wetted materials CIP, SIP cleanable.
|
Transmitter features |
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
|
Nominal diameter range |
DN 2 to 150 (¹⁄₁₂ to 6")
|
Wetted materials |
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum
|
Measured variables |
Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected conductivity
|
Max. measurement error |
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option) ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
|
Measuring range |
0.06 dm³/min to 600 m³/h (0.015 gal/min to 2 650 gal/min)
|
Max. process pressure |
PN 40, Class 150, 20K
|
Medium temperature range |
–20 to +150 °C (–4 to +302 °F)
|
Ambient temperature range |
–40 to +60 °C (–40 to +140 °F)
|
Sensor housing material |
1.4301 (304), corrosion resistant
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4409 (CF3M), similar to 316L
|
Transmitter housing material |
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
|
Degree of protection |
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure
|
Display/Operation |
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
|
Outputs |
4 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Relay output
|
Inputs |
Status input
4-20 mA input
|
Digital communication |
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
|
Power supply |
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
|
Hazardous area approvals |
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC
|
Product safety |
CE, C-tick, EAC marking
|
Functional safety |
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
|
Metrological approvals and certificates |
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
|
Marine approvals and certificates |
LR approval, DNV approval, ABS approval, BV approval
|
Pressure approvals and certificates |
PED, CRN
|
Material certificates |
3.1 material
|
Hygienic approvals and certificates |
EHEDG, 3-A, liner and seals acc. to FDA, cGMP
|